HR1234W

 

Cells Per Unit 6
Voltage Per
Unit
12 V
Capacity 34W @ 15 minute-rate to 1.67V per cell @ 25°C (77°F)
Weight Approx. 2.50kg. (5.51lbs.)
Maximum Discharge current 100/130A (5sec.)
Internal Resistance Approx. Approx. 19mΩ
Operating Temperature Range Discharge:-15℃~50℃(5°F~122°F)
Charge:-15℃~40℃(5°F~104°F)
Storage:-15℃~40℃(5°F~104°F)
Nominal Operating Temperature Range 25°C ± 3°C (77°F ± 5°F)
Float charging voltage 13.5 to 13.8 VDC/unit Average at 25°C (77°F)
Recommended Maximum Charging current limit 3.4A
Equalization and Cycle Service 14.4 to 15.0 VDC/unit Average at 25°C (77°F)
Self Discharge It should be more than 75% of the capacity that before storage after stocked for 6 months at ambient temp. 25℃
Terminal F2-Faston Tab250
Container Material ABS(UL94-HB) & Flammability resistance of(UL94-V0) can be available upon request.